professional factory provide Rubber glove-household-L to Rome Factories

Short Description:

Sanitation glove, made of 100% natrual latex, length 32-36cm, textured palm for anti-slip, waterproof, anti acid and alkali, non-toxic.  Mainly used for food processing, hotels, family kitchen, etc. Color: red, yellow, orange, rose, nude, etc.


Product Detail

FAQ

Product Tags

Our products are widely recognized and trusted by users and can meet continuously developing economic and social needs. professional factory provide Rubber glove-household-L to Rome Factories, Standing still today and looking into the future, we sincerely welcome customers all over the world to cooperate with us.


Sanitation glove, made of 100% natrual latex, length 32-36cm, textured palm for anti-slip, waterproof, anti acid and alkali, non-toxic. 

Mainly used for food processing, hotels, family kitchen, etc. Color: red, yellow, orange, rose, nude, etc.

  • Previous:
  • Next:
  • FAQ Content




  • As an avid gardener I was tired of using gloves that wore out quickly. I was sure there had to be a better solution. I looked at what was available, & when I couldn’t find something better, I made my own. Let me know what you think.
    We’re currently looking to get picked up by Chain stores & working heavily on marketing. Look for us in catalogs, online retailers, magazines… and new stores are signing on every day. Get you a pair.
    The Gardening Tool That Fits Like A Glove! TM.



    شرکت مشاورین پوششهای صنعتی کسری در راستای کاهش خطرات و صدمات ناشی از برق گرفتگی و با بهره گیری از تکنولوژی روز اروپا موفق به تولید سفارشی کفپوش عایق برق – دارای گزارش آزمون از آزمایشگاه فشارقوی پژوهشگاه نیرو و مرکز پژوهش متالوژی رازی و دانشگاه صنعت آب و برق وزارت نیرو(شهید عباسپور) شده است.
    کفپوش عایق برق طبقه خاصی از کفپوش های پلیمری عایق با خواص ضد الکتریکی عالی میباشد که برای استفاده در مقابل تابلوهای برق، پستهای برق و ایستگاههای فشار قوی کاربرد دارد. کفپوش عایق برق اپراتورها یا کارکنان واحد نگهداری و تعمیرات تجهیزات الکتریکی را در برابر برق گرفتگی و شوک های الکتریکی احتمالی محافظت مینماید و باید در مکانهایی که احتمال خطرات جانی و ایمنی وجود دارد مورد استفاده قرار گیرد.

    ثابت ماندن خواص عایقی لاستیک با طرز ترکیب آن ( کامپاندینگ ) مرتبط می باشد و هر گونه ماده افزودنی (رنگ ها و فیلر ها ، مواد محافظ و پروسه پخت ) در میزان مقاومت الکتریکی
    لاستیک تاثیر گذار خواهد بود.

    آدرس : تهران ـ خيابان شريعتی ـ پایین تر از دوراهی قلهک
    انتهای کوچه مسعود- کوچه مطهری-پلاک11
    تلفاکس: 94-22635491 و 10-22630608

    Kasra Company is one of the chief manufacturers and exporters of Electrical Insulating Mats in Middle East. As an eminent manufacturer, we provide electrical insulating mats according to IEC 61111 International Standard. Electrical insulating mats are used in front of switchboards or high voltage equipments to protect working personnel against deadly electrical shocks. We can supply the electrical insulating mats in the form of roll for both HV & LV applications in 1 m width and any length as per customer requirements.
    Unique characteristics of our electrical insulating mat:
    - Class 0 to Class 4, Maximum use voltage 36kV (A.C) 54Kv (D.C)
    - Suitable physical and mechanical properties to withstand trolley movement, mobile electrical equipments and foot traffic
    - Applicable for both AC & DC electrical insulation
    - Water and moisture resistance
    - Appropriate anti-skid properties
    - Excellent resistant against tearing and punching
    - Fire retardant, self-extinguishing properties
    - Exhibit good elongation & tensile strength properties
    - Manufactured without any metallic derivatives or carbon additives
    - Applicable for all fields of generation, transferring, distribution and consumption of electricity
    - Available in blue, gray, green, orange and red colors

    Office address : No. 11, Motahari Alley, Masoud Alley, Shariati Ave (Gholhak), Tehran, Iran.

    Telefax: (+98) 021-26400037-9
    (+98) 021-26423949

    (+98) 021-22263329

    Email: info@kasracompany.com

    Electrical insulating matting in plane form shall be tested as received, without modification. In the case of electrical insulating matting in rolls, having a width equal to or larger than
    1 000 mm, the minimum size of each test piece shall be 1 000 mm × 1 000 mm. For rolls having a width less than 1 000 mm, the test piece shall have the length equal to the width.
    The electrical insulating matting or test piece shall be given a voltage test as specified in Table 4 using electrodes as specified in 5.6.2.2. The voltage shall be initially applied at a low
    value and gradually increased at a constant rate-of-rise of approximately 1 000 V/s until the specified test voltage level is reached. The test period shall be considered to start at the
    instant the specified voltage is reached.The test shall be considered as passed if the specified test voltage is reached and maintained for 3 min without the occurrence of disruptive discharge or other electrical failure. For conformity testing, the matting does not have to be submitted to a conditioning for moisture absorption. The time duration of the proof test, shall be 1 min.
    In case of matting in a roll, an alternative test for testing the entire length of each roll is under consideration (for example, a test set up made of a roller to hold the roll to be tested, a feed
    table at an appropriate speed with rollers energized at an appropriate test voltage, a take-up support table and take-up rollers).

    Send your message to us:

    INQUIRY NOW
    • [cf7ic]

    Related Products

    INQUIRY NOW
    • [cf7ic]