Heavy duty rubber glove, made of 100% natural latex. 32″ length(82cm), smooth finish, seamless, cotton lining, left/right hand, 800g/pair, 50 pairs/case. Using for Isolater, dry box, blast cabinet, etc.
Product Detail
FAQ
Product Tags
The company upholds the philosophy of "Be No.1 in quality, be rooted on credit and trustworthiness for growth", will continue to serve old and new customers from home and overseas whole-heatedly. 12 Years Factory wholesale 32″ rubber glove-cotton linning sale to Bhutan, We welcome new and old customers from all walks of life to contact us for future business relationships and mutual success!
Heavy duty rubber glove, made of 100% natural latex. 32″ length(82cm), smooth finish, seamless, cotton lining, left/right hand, 800g/pair, 50 pairs/case. Using for Isolater, dry box, blast cabinet, etc.
FAQ Content
Learn how to down load Android applications on Google Enjoy.
https://assist.google.com/googleplay/remedy/113409
شرکت مشاورین پوششهای صنعتی کسری در راستای کاهش خطرات و صدمات ناشی از برق گرفتگی و با بهره گیری از تکنولوژی روز اروپا موفق به تولید سفارشی کفپوش عایق برق – دارای گزارش آزمون از آزمایشگاه فشارقوی پژوهشگاه نیرو و مرکز پژوهش متالوژی رازی و دانشگاه صنعت آب و برق وزارت نیرو(شهید عباسپور) شده است.
کفپوش عایق برق طبقه خاصی از کفپوش های پلیمری عایق با خواص ضد الکتریکی عالی میباشد که برای استفاده در مقابل تابلوهای برق، پستهای برق و ایستگاههای فشار قوی کاربرد دارد. کفپوش عایق برق اپراتورها یا کارکنان واحد نگهداری و تعمیرات تجهیزات الکتریکی را در برابر برق گرفتگی و شوک های الکتریکی احتمالی محافظت مینماید و باید در مکانهایی که احتمال خطرات جانی و ایمنی وجود دارد مورد استفاده قرار گیرد.
ثابت ماندن خواص عایقی لاستیک با طرز ترکیب آن ( کامپاندینگ ) مرتبط می باشد و هر گونه ماده افزودنی (رنگ ها و فیلر ها ، مواد محافظ و پروسه پخت ) در میزان مقاومت الکتریکی
لاستیک تاثیر گذار خواهد بود.
آدرس : تهران ـ خيابان شريعتی ـ پایین تر از دوراهی قلهک
انتهای کوچه مسعود- کوچه مطهری-پلاک11
تلفاکس: 94-22635491 و 10-22630608
Kasra Company is one of the chief manufacturers and exporters of Electrical Insulating Mats in Middle East. As an eminent manufacturer, we provide electrical insulating mats according to IEC 61111 International Standard. Electrical insulating mats are used in front of switchboards or high voltage equipments to protect working personnel against deadly electrical shocks. We can supply the electrical insulating mats in the form of roll for both HV & LV applications in 1 m width and any length as per customer requirements.
Unique characteristics of our electrical insulating mat:
- Class 0 to Class 4, Maximum use voltage 36kV (A.C) 54Kv (D.C)
- Suitable physical and mechanical properties to withstand trolley movement, mobile electrical equipments and foot traffic
- Applicable for both AC & DC electrical insulation
- Water and moisture resistance
- Appropriate anti-skid properties
- Excellent resistant against tearing and punching
- Fire retardant, self-extinguishing properties
- Exhibit good elongation & tensile strength properties
- Manufactured without any metallic derivatives or carbon additives
- Applicable for all fields of generation, transferring, distribution and consumption of electricity
- Available in blue, gray, green, orange and red colors
Office address : No. 11, Motahari Alley, Masoud Alley, Shariati Ave (Gholhak), Tehran, Iran.
Telefax: (+98) 021-26400037-9
(+98) 021-26423949
(+98) 021-22263329
Email: info@kasracompany.com
Electrical insulating matting in plane form shall be tested as received, without modification. In the case of electrical insulating matting in rolls, having a width equal to or larger than
1 000 mm, the minimum size of each test piece shall be 1 000 mm × 1 000 mm. For rolls having a width less than 1 000 mm, the test piece shall have the length equal to the width.
The electrical insulating matting or test piece shall be given a voltage test as specified in Table 4 using electrodes as specified in 5.6.2.2. The voltage shall be initially applied at a low
value and gradually increased at a constant rate-of-rise of approximately 1 000 V/s until the specified test voltage level is reached. The test period shall be considered to start at the
instant the specified voltage is reached.The test shall be considered as passed if the specified test voltage is reached and maintained for 3 min without the occurrence of disruptive discharge or other electrical failure. For conformity testing, the matting does not have to be submitted to a conditioning for moisture absorption. The time duration of the proof test, shall be 1 min.
In case of matting in a roll, an alternative test for testing the entire length of each roll is under consideration (for example, a test set up made of a roller to hold the roll to be tested, a feed
table at an appropriate speed with rollers energized at an appropriate test voltage, a take-up support table and take-up rollers).